CN|EN
> Products > Product Detail

20 kg-Class Ultra-Compact Active Hydrogen Maser — JLT-2520 PRO

Model: JLT-2520 PRO

The JLT-2520 PRO (ECNU-2520 PRO) active hydrogen maser uses an innovative high-Q, low-temperature-drift dielectric microwave cavity together with an integrated getter-and-ion combination pump. This enables the JLT-2520 PRO to provide a standard frequency source with highly stable, low-noise sine wave outputs (5 MHz, 10 MHz, 100 MHz) and a one-pulse-per-second signal (1PPS), with a daily stability better than 8.0×10⁻¹⁶. Its specifications are benchmarked against the VCH2020, and it is a 100% domestically produced substitute.

Applications

  • · Time service;
  • · Metrology and testing;
  • · Space tracking and navigation;
  • · Radio astronomy / VLBI;
  • · Scientific research.

Specifications

Waveform Qty Amplitude Bandwidth, ps Rise time, ns Interface / Load
5 MHz (sine) 2 1 ± 0.2 VRMS - - SMA/50Ω
10 MHz (sine) 2 1 ± 0.2 VRMS - - SMA/50Ω
Performance
Relative frequency accuracy ± 3×10⁻¹³ ≤ ±1×10⁻¹³
Frequency stability (Allan deviation at 25±1 °C, environmental effects excluded) 1 s ≤ 3.0×10⁻¹³
10 s ≤ 1.0×10⁻¹⁴
100 s ≤ 3.0×10⁻¹⁵
1000 s ≤ 1.0×10⁻¹⁵
3600 s ≤ 8.0×10⁻¹⁶
86400 s ≤ 5.0×10⁻¹⁶
Phase noise
(dBc/Hz)
Offset @5MHz @10MHz @100MHz
1 Hz ≤ -118 ≤ -112 ≤ -92
10 Hz ≤ -135 ≤ -129 ≤ -109
100 Hz ≤ -149 ≤ -143 ≤ -122
1 kHz ≤ -156 ≤ -149 ≤ -122
10 kHz ≤ -158 ≤ -153 ≤ -153
Frequency drift (after 1 year of operation) ≤ 5×10⁻¹⁶/day
Magnetic sensitivity ≤ 2×10⁻¹⁴/Gauss
Temperature sensitivity ≤ 5×10⁻¹⁵/℃
Physical Specifications
Dimensions (W × H × D) 470 mm × 223 mm × 530 mm
Weight ~10kg
Operating temperature range (±0.5 °C/hour) 10–35 °C (recommended +22 °C)
Relative humidity < 80% at +25 °C